M-95 Spec Sheet: 

Spec Sheet | Drawings | Literature

You can copy and paste this information into your word processor.

Enclosure
NEMA 4X FRP (Fiberglass reinforced polyester)
18" H x 16" W x 9" D
Two (2) padlockable stainless steel latches

Power Required
120 VAC / i PH / 60 HZ (Standard)

Circuit Breaker
20 AMP

Motor
1/2 H.P. 100% continuous duty cycle, TEFC, 1.15 Service Factor

Pump
Fixed displacement steel gear(Flow rates from 0.24 - 1.15 G.P.M.)

Bypass Relief
Adjustable to operating system requirements

Pressure Settings
Variable 100 - 2,000 P.S.I.

Pressure Switch
Adjustable to operating system requirements

Pressure Gauge
2.5" liquid filled 0 - 3,000 P.S.I.

System Timer
0 - 10 minutes

Tank Level Switch
Single Pole Double Throw

Operating Modes
"REMOTE" / "OPEN" / "CLOSE"

Manual Controls
"OPEN"
"CLOSE"
"EMERGENCY STOP" palm button

Diagnostic Lights
"Breaker ON"
"Power ON"
"Remote"
"Open"
"Close"
"E-Stop engaged"

Weight
65 Lbs. (Dry)

Copyright 2010 Pratt Control Systems. All rights reserved. Pratt Control Systems is a subsidiary of Mueller Water Products, Inc.
Read our privacy policy.
Henry Pratt | Hydro Gate